be quiet! BL094 Cooler
Overview
BEQ-BL094-00 is a be quiet! workstation or chassis fan used as a field-replaceable cooling component in multiple Exxact systems. Across these tickets it appears as a front or chassis case fan handled through component RMA, advance replacement, and occasional bundled cooling-part service with liquid coolers.
Known Issues
-
Fan Speed Issues , 10 tickets
The recurring product problem is abnormal fan behavior: squealing, wobble, blade contact, loud failure, intermittent non-spin, or repeated stop-start cycling. Representative tickets: #18894, #21703, #22975, #32480, #40029, and 5 more. -
Overheating , 4 tickets
Several cases tie the fan failure to broader cooling risk, including systems with boot or cooler concerns where the failed fan was part of the thermal path. Representative tickets: #18894, #24465, #24867, #32307. -
RMA Workflow , 10 tickets
Every ticket here is handled operationally as a replacement or return workflow, often with exceptions for advance replacement when the workstation cannot go down. Representative tickets: #21703, #22975, #35321, #35680, #40029, and 5 more.
Common Questions
-
What failure modes show up most often?
Noise is the dominant complaint: squealing, wobbling, blade rub, and loud failure. Several tickets also report intermittent stopping or failure to spin entirely (#18894, #21703, #22975, #32480, #40029). -
Does Exxact require return-before-replacement?
Standard flow is usually return-first, but Exxact repeatedly made advance-replacement exceptions when the workstation had to remain in service (#22975, #24465, #32480, #35321, #40029). -
Can the fan be replaced as a component without returning the whole system?
Usually yes. Most tickets were component-only RMAs for the fan itself, though one case paused because a separate boot issue might have justified a full-system return (#21703, #22975, #32307, #35321). -
What can block warranty replacement?
Physical damage matters. In one case, cut fan connectors made two returned fans ineligible for replacement even though the original complaint was valid (#35680). -
Is this fan ever handled together with other cooling parts?
Yes. Some tickets bundled BEQ-BL094-00 with Enermax liquid-cooler parts or other cooling fans in the same RMA flow (#18894, #24465, #24867).
Related Products
- EMX-ELC-LTTRTO240-TBP-00 , commonly paired in the same cooling-service tickets when the system also had a suspect liquid CPU cooler (#18894, #24867).
- Other be quiet! chassis fans in the same workstation family , several tickets describe multiple identical case fans failing across one or two systems, suggesting customers may encounter the part as a matched set rather than a single standalone SKU (#24465, #35680).
- Workstation chassis fan assemblies vs. full-system RMA , ticket #32307 shows a common confusion pair: a simple BEQ-BL094-00 fan replacement can be delayed when a separate boot issue raises the question of whether the whole workstation should come back instead.
Referenced by
- Fan Speed Issues — issue affecting this product (×10)
- RMA Workflow — issue affecting this product (×10)
- CPU Cooler Failure — issue affecting this product (×1)
- System Boot Failure — issue affecting this product (×1)